Shell and Tube Heat Exchanger
OSC77FD211TH
Features
-The appratus is used for studying heat transfer through a shell and tube heat exchanger under parallel or counter flow conditions-The unit consists of a shell and tube heat exchanger, hot water tank with a transfer pump, instruments for monitoring and control
-Parallel and counter flow is selected by cold water control valves
Typical Experiments
-Study of heat transfer under parallel and counter flow at various rates of flow and temperature differences-Heat transfer coefficient at various rates of flow and temperature differences
| Model | OSC 77FD 211TH | |||||||
| Construction | Insulated stainless steel shell with 7 stainless steel inner tubes | |||||||
| Total heat transfer area over 600cm2 | ||||||||
| Temperature sensor | 4 ea for hot and cold water inlets and outlets | |||||||
| 1 ea for hot water tank | ||||||||
| A service module | A hot water pump | |||||||
| A stainless steel hot water tank with a level switch to prevent heater operation | ||||||||
| if level is too low | ||||||||
| Heater : 3000W | ||||||||
| 2 sets of temperature indicator with selector switch | ||||||||
| Temperature control unit to limit temperature of hot water to not more than 80℃ | ||||||||
| Flow meters : Hot water 0.4 to 4L/m, Cold water 1 to 7L/m | ||||||||
| Power supply | 220V 1Ph 50Hz. Other power supply is available on request | |||||||
| Size (W x L x H) | Approx. 650 x 1400 x 650 mm | |||||||
| Weight | Approx. 65 kg | |||||||